PI Vision value symbol with an ad hoc trend one click away
Value+ shows a PI Point or AF attribute value with a configurable tooltip, a button to copy its label and a floating ad hoc trend, and it can show the value at a set time or as a summary over a time range.
Value+ v2.0 in PI Vision: a hovered value with its tooltip and quick actions, and the floating Quick Trend it opened. Demo data. Select the image to enlarge.
PI Vision value tooltips with tag names and point attributes
Hover over a value to see where it comes from, without opening another display or the PI System Explorer.
Tooltips with the label you choose
Show the label that helps your users most, such as the tag name behind an AF attribute or its full path.
Label as asset and attribute, asset, attribute, description, path, tag name, tag path or your own text.
Value, units, timestamp and a custom text line in the tooltip.
Tooltip above or below the value, with your text, background and border colours and font size.
Switch the tooltip off for values that need no extra context.
The tooltip with the tag name as label, a custom text and PI Point attributes, and the three quick actions. Demo data. Select the image to enlarge.
PI Point attributes and a copy button
Give engineers the point configuration they look up most, and let them copy the label in one click.
PI Point attributes such as instrumenttag, pointsource, pointtype or datasecurity in the tooltip, in the order you set.
Available for PI Points and AF attributes with a PI Point data reference.
Copy Label puts the label shown in the tooltip, such as the tag name, on the clipboard.
Administrators can set tooltip and Copy Label defaults for every Value+ in the Vision Library+ configuration file.
Quick actions, tooltip content and point attributes in the Interactivity settings. Select the image to enlarge.
Ad hoc trends from PI Vision values
See how a value got where it is without leaving the display: Value+ opens a floating trend of its data source.
Open a floating Quick Trend from the value
Check the recent history of a value in place and close the chart when you are done.
A Quick Trend button appears next to the value when you hover over it.
The trend opens for the display time range and floats above the display; move and resize it as needed.
Change the duration from one hour to one year, use multiple scales, and read current, minimum, maximum and average values in the summary table.
Select a period in the chart to see the statistics for just that range. Switch the Quick Trend off per symbol where it is not wanted.
A Quick Trend with three traces and a selected range; the summary table shows the statistics for that range. Demo data. Select the image to enlarge.
Compare several values in one trend
Build a comparison on the fly from the values already on the display.
While a Quick Trend is open, a second button adds the hovered value to it as another trace.
Traces from different tags and units share one chart, each with its own scale.
Hide a trace or remove it from the chart in the summary table.
No configuration needed: the chart uses the data source of each Value+ symbol.
Add to active Quick Trend: three values from the display in one floating chart. Demo data. Select the image to enlarge.
Current, historical and summary values in PI Vision
Show the latest value, the value at a chosen time, or a summary of a period, each with the formatting and data quality checks it needs.
Values at a display time or a PI time
Pin a value to the start or end of the display time range, or to a time of your own.
Time: display end time, display start time or a custom PI time such as t, -2d or t+10m.
An offset in minutes, hours, days, weeks, months or years from the display start or end time.
Exact shows only a value recorded at exactly that time; without it, the latest value before that time.
Number formats, units of measure conversion and date and time formats, including relative times.
Values at custom PI times (-2d, t+10m, t) and the Recorded settings. Demo data. Select the image to enlarge.
Summary values over a time range
Show a total, average or other aggregate of a period next to the current values.
Total, average, minimum, maximum, range, standard deviation, population standard deviation, count or percent good.
Time-weighted or event-weighted calculation.
Over the display time range, a custom start and end time, or a duration and offset.
Several Value+ symbols on one data source show different aggregates side by side, each with your own label.
Current value, 24-hour average, minimum and maximum of one tag, with the Summary settings. Demo data. Select the image to enlarge.
Long text, colours and data quality
Keep text values readable and warn users when a live value has stopped updating.
Multiline text for string values: split at a delimiter or wrap long text.
Stale warning: an amber clock when a live value is older than the time you set, with the last event, data age and threshold in the tooltip.
Hide No Data hides the value where an asset has no data, for example on templated displays.
Fill, text and value colours, alignment and fonts, plus PI Vision multi-state colours.
A multiline string value, the stale warning with its tooltip details, and the Data Quality and Multiline settings. Demo data. Select the image to enlarge.
PI Vision value symbol examples with Value+
Four common ways teams set up Value+ on their displays.
Instrument check
Data
An AF attribute with a PI Point data reference
Settings
Tooltip label Tag, point attributes instrumenttag and pointsource, Copy Label on
Shows
The tag name and instrument tag on hover, and the tag name ready to paste into another tool
The average of the last eight hours next to the current value
Start-of-day value
Data
A counter or level PI Point
Settings
Recorded mode, Time Custom t, Exact off
Shows
The value at midnight, or the last one recorded before it, for a daily comparison
Templated asset display
Data
An AF attribute that some assets of the template do not have
Settings
Hide No Data on, Stale warning after 2 hours, Quick Trend on
Shows
No No Data text on assets without the attribute, an amber clock on values that stopped updating, a trend on demand
Related symbols: KPI Card+ to present one number as a dashboard card with a target and sparkline, Radial Gauge+ and Linear Gauge+ to show values on a scale with ranges, and Alarm Sound+ for an audible alarm when a value crosses a threshold.
When should we use Value+ instead of KPI Card+ or the PI Vision value symbol?
Value+ is an improved version of the PI Vision value symbol. Use it where users need more than the number: a tooltip with the tag name, path or point attributes, a copy button, a floating ad hoc trend, a value at a set time, a summary over a time range, multiline text or data quality warnings, without adding a full chart. Use KPI Card+ when one number deserves a dashboard card with a target badge, a sparkline and card-level status; Value+ has no card surface or container style by design. Administrators can also replace every PI Vision value symbol with Value+ in the Vision Library+ configuration: existing value symbols become Value+ and the original symbol is hidden from the symbol bar.
What is the ad hoc trend in Value+?
It is a floating Quick Trend of the value’s data source. Hover over the value and select the Quick Trend button to open the chart for the display time range. While a Quick Trend is open, a second button adds further values to it. The chart can be moved and resized, offers multiple scales, duration buttons, a range selection with statistics and a summary table, and closes with its close button.
Can administrators set Value+ defaults for all displays?
Yes. In the Vision Library+ configuration file, administrators can switch on Copy Label for every Value+, set the tooltip text, background and border colours, the font size and the label type, choose PI Point attributes that every tooltip shows, and hide the tooltip. These settings apply to existing and new Value+ symbols and take precedence over each symbol’s own settings. Hide No Data and the stale warning can be enforced site-wide in the same way.
How does Value+ handle stale or missing data?
Stale warning shows an amber clock when a live current value’s timestamp is older than the Stale after time you set, and adds the last event time, the data age and the threshold to the tooltip. It uses event timestamps, so it does not detect a frozen sensor whose value PI keeps writing with new timestamps, and it does not apply to historical, custom-time, offset or summary values. Hide No Data hides only the exact PI No Data state; other bad values stay visible.
What do we need to run it?
PI Vision 2021 or later with PI Web API, and PI AF Server 2018 SP2 or later. Value+ reads through PI Web API as the signed-in PI Vision user, so your PI Data Archive and AF security decide what each user can see.
How do we get Value+?
Value+ is part of Vision Library+, together with the other Vision Library+ symbols. Request a trial to test it in your own PI Vision environment.
Try Value+ in your PI Vision
Value+ is included in Vision Library+, the PI Vision custom symbol library from Software Athlete. Test it on your own displays and data.