Vision Audit+ / Reference
Feature Switches
This chapter lists the switches that turn Vision Audit+ features on and off.
Overview
This chapter lists the switches that turn Vision Audit+ features on and off.
Each switch exists twice: as an AF configuration attribute that the service reads, and as a key in the toolbar configuration file vap-config.js that decides which panes PI Vision shows. The Configuration Utility writes both (PI Vision Toolbar page, Install). The toolbar's Configuration view shows them read-only.
| AF attribute | vap-config.js key | Default | Feature |
|---|---|---|---|
EnableDisplayHistory | EnableDisplayHistory | true | Display History pane, change tracking, revert, recycle bin, snapshots |
EnableValidation | EnableValidation | false | Display Validation pane and validation workflow |
EnableDataSources | EnableDataSources | false | Data Sources and Display Usage panes, data source index, display health check |
EnableDataExport | none | false | data export from Data Sources and Display Usage; needs EnableDataSources |
A key missing from vap-config.js counts as its default. When EnableDisplayHistory, EnableValidation and EnableDataSources are all off, the toolbar shows a single Vision Audit+ pane with the System Status view.
vap-config.js also holds PIWebApiUrl (/piwebapi when PI Web API runs on the PI Vision server), AFServer, AFDatabase and the legacy key EnableDisplayHealth.