Documentation Vision Audit+ Documentation

Vision Audit+ / Reference

Feature Switches

This chapter lists the switches that turn Vision Audit+ features on and off.

Overview

This chapter lists the switches that turn Vision Audit+ features on and off.

Each switch exists twice: as an AF configuration attribute that the service reads, and as a key in the toolbar configuration file vap-config.js that decides which panes PI Vision shows. The Configuration Utility writes both (PI Vision Toolbar page, Install). The toolbar's Configuration view shows them read-only.

AF attributevap-config.js keyDefaultFeature
EnableDisplayHistoryEnableDisplayHistorytrueDisplay History pane, change tracking, revert, recycle bin, snapshots
EnableValidationEnableValidationfalseDisplay Validation pane and validation workflow
EnableDataSourcesEnableDataSourcesfalseData Sources and Display Usage panes, data source index, display health check
EnableDataExportnonefalsedata export from Data Sources and Display Usage; needs EnableDataSources

A key missing from vap-config.js counts as its default. When EnableDisplayHistory, EnableValidation and EnableDataSources are all off, the toolbar shows a single Vision Audit+ pane with the System Status view.

vap-config.js also holds PIWebApiUrl (/piwebapi when PI Web API runs on the PI Vision server), AFServer, AFDatabase and the legacy key EnableDisplayHealth.