Troubleshooting Scans and Connections

This chapter helps you find why scans fail or fall behind, and where each kind of target's own problems are covered. Installation problems (installer, website, database connection, license) are in Installation Troubleshooting in the Installation Guide.

Overview

This chapter helps you find why scans fail or fall behind, and where each kind of target's own problems are covered. Installation problems (installer, website, database connection, license) are in Installation Troubleshooting in the Installation Guide.

Where to look first

Work through these in order: the Scanning page's Needs attention tab, the Targets tab (worst first, with separate Inventory and Health columns), the failed run opened from History, the logs (see Support and Diagnostics), and finally a support bundle, whose scan-automation.json shows why work did or did not run.

Note: Test on an Admin page runs as the web application's identity, while scans run as the scanner service's identity. A passing test proves only the first. If the two identities differ, give both the same PI and AF read access.

Scanning

SymptomCauseFix
Scanning Status reads Needs action with nothing failingAutomatic monitoring was never started, or is paused, and health is getting oldStart or resume it under Admin > Scan Automation
A target stays on awaiting inventoryIts first full scan has not succeededOpen its last inventory run and fix the cause; no health refresh runs until the baseline succeeds
Health fails while inventory succeedsA source or permission problem on the health path, or too many objects could not be resolvedRead the health run's failures; check read access to the PI Points behind AF attributes
A queued item never startsFull verification waits for the heavy-work windowWait for the window, or use Run now on the Queued tab
Freshness does not move after a scanThe scan was narrowed to some PI Point rules, or did not succeedRun an unscoped scan
An enabled target is never scanned automaticallyAutomatic is cleared for it, or the license does not name the PI Data ArchiveTick Automatic under Admin > Scan Automation; install a license that names the archive
Test passes but the target's scans fail with access errorsScans run as the scanner service identity, which lacks the read access the web application's identity hasGive both identities the same PI, AF and SQL read access

Problems with one kind of target

Problems with one kind of target are in the troubleshooting table at the end of its chapter: PI Data Archives (including the Module Database and the runtime poll), AF Servers and Databases, OpenID Connect, PI Vision Instances, PI Adapter Monitoring and Host Monitoring.